Cleanroom Design and Clean Room Design Services

American approaches your design with a simple yet proven method in cleanroom principles. Whether you already have a preliminary drawing or need complete cleanroom design services, we can provide you with a simple, cost effective system that meets your needs.

Cleanroom CAD Generated Drawings Cleanroom Technology

American Cleanroom Systems provides clear and easy-to-read CAD generated drawings to help you visualize your cleanroom.

American Cleanroom Systems offers state-of-the-art technology at competitive prices.

Cleanroom Design Services

Cleanroom Design Services

  • Licensed General Contractor
  • Engineering
  • On-Site Management To Save You Cost
  • Architectural Design
  • Structural Design
  • Electrical
  • HVAC
Cleanroom Design Options

Cleanroom Design Options

  • Class 1 through Class 100,000 to meet Federal STD. 209E / ISO14644-1
  • Temperature Control
  • Humidity Control

Cleanroom Design Guidelines

SI ISO 14644-1 ROOM CLASS Maximum allowable count per cubic foot of air.
0.1p 0.2p 0.3p 0.5p 5p
  Class 1            
M1 Class 2 0          
M1.5 Class 3 1 35 7.5 3 1  
M2.5 Class 4 10 350 75 30 10  
M3.5 Class 5 100   750 300 100  
M4.5 Class 6 1,000       1000 7
M5.5 Class 7 10,000       10000 70
M6.5 Class 8 100,000       100000 700

All Guidelines and Criteria are approximates.

CRITERIA CLASS 10 M2.5
ISO 4
CLASS 100 M3.5
ISO 5
CLASS 1,000 M4.5
ISO 6
CLASS 10,000 M5.5
ISO 7
CLASS 100,000 M5.5
ISO 8
Air Changes Per Hr / Min Per Hour/Per Minute   500-600/8-10 300 To 480
5 To 8
180/3 60/1 30/.5
Filter Coverage % 90 to 100 50 to 70 20 to 30 7 to 15 4 to 5
CFM Per Square Foot 85 to 90 36 to 65 18 to 32 9 to 16 4 to 8
Filter Efficiency 99.9997
(5-9s ULPAs)
99.997
(4-9s HEPAs)
99.997
(4-9s HEPAs)
99.997
(4-9s HEPAs)
99.97
(3-9s HEPAs)
Type of Ceiling 2" Aluminum Painted Grid 2" Aluminum Painted Grid 2" Aluminum Painted Grid 1 1/2" T-Bar Conventional 1 1/2" T-Bar Conventional
Light Fixture Type Tear Drop or
Flow Thru
Tear Drop or 2'x4' C/R Fixture 2' X 4' Cleanroom Fixture 2' X 4' Cleanroom Fixture 2' X 4' STD Fixture Field Sealed
Ceiling Panels FRP or Epoxy Painted FRP, Vinylrock or Mylar Vinylrock or Mylar Vinylrock or Mylar Vinylrock or Mylar
Wall System Modular Modular Modular Modular or Drywall Modular or Drywall
Floor Covering Heat Weld Vinyl or Poured Epoxy Heat Welded Sheet Vinyl Solvent Welded Sheet Vinyl Sheet Vinyl or VCT Sheet Vinyl or VCT
Flooring Base 2" to 6' Cove Cove or Aluminum Base Channel Cove or Aluminum Base Channel Cove or Aluminum Base Channel Cove or Aluminum Base Channel
Air Returns Raised Floor or Center Returns Low Wall on Long Axis Low Wall at Perimeter Low Wall Low Wall or Ceiling

All Guidelines and Criteria are approximates.